A-A-1671B
B. Testing requirements - Inspection Level S-1 with an Acceptable
Quality Level (AQL) of 4.0 percent defective. The sample unit shall be one roll. TAPPI tests shall be performed in accordance with TAPPI T400. The tests shall be as follows:
TESTS |
METHOD |
REQUIREMENT LOCATION |
Basis weight |
TAPPI T410 |
Para. 1A |
Adhesiveness |
See para. 2C |
Para. 1B |
Tensile Strength |
TAPPI T404 |
Para. 1D & Table I |
(Type I) Softening Point |
ASTM D36 |
Para. 1E |
(Type II) Water Resistance |
TAPPI UM 575 |
Para. 1F |
Performance |
See para. 2D |
Para. 1H |
c. Adhesiveness test:
Testing conditions: This test shall be performed in an atmosphere maintained at standard conditions as specified in TAPPI method T
402. The test paper shall be conditioned to equilibrium with these conditions prior to testing. The tape specimens shall not be conditioned prior to testing.
Test: Cut four (4) 12” X 6” specimens of standard reference material, as specified in ASTM D 36542/, two each in machine direction (MD) and cross direction (CD). Cut and completely moisten 4 randomly selected tape test specimens 12 inches long by the full tape width, utilizing an automatic dispenser conforming to CID A-A- 79. Fold over one inch of the tape end so that the adhesive sides are together to form a one inch tab to facilitate tape removal efforts. At the end of 15 seconds, apply each tape specimen to the test paper, 2 in MD and 2 in CD of the standard reference material. Roll the tape once in each direction with a soft rubber covered hinged iron roller, weighing 16 pounds + 1/4 lb., 3-1/2 in. + 1/8 in. wide and having an overall diameter of 5 in. + 1/8 in. at a rate of 12 inches/min. Within 5 seconds after the tape is applied on the paper, gently lift the tab to expose not more than 3 inches of the tape (one MD and one CD) and observe the tackiness of the gum. The gum shall show, a pronounced tackiness. (The portion of the specimens lifted to observe tackiness shall not be reapplied.) After twenty-
Pour hours elapsed time, determine the ease of removal of the specimens (2 MD and 2 CD). The adhesive quality shall be considered satisfactory if:
2/ Mosinee Paper Corporation, Mosinee, Wi. 54455, telephone
(715) 693-2111. Mosinee paper, 767, 120# basis wt., neutral paper may be used as a substitute for the standard reference material 1810, specified in ASTM D 3654.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business